Description
Management and Monitoring
Management and monitoring refer to the processes and tools used to manage and monitor a network interface controller (NIC) and its associated network connections.
NICs can be managed and monitored using a variety of methods, including web-based graphical user interfaces (GUIs), command-line interfaces (CLIs), and third-party management software. These tools allow administrators to view information about the NIC’s performance, configure settings, and monitor the status of network connections.
Some NICs also support remote management and monitoring, allowing administrators to manage and monitor NICs across multiple servers from a central location. This can include the ability to remotely configure settings, monitor performance metrics, and receive alerts in the event of issues or failures.
In addition to providing management and monitoring capabilities for individual NICs, some management software can also provide a centralized view of the entire network infrastructure, including switches, routers, and other network devices. This can provide a comprehensive view of the network and help administrators identify issues or bottlenecks that may be impacting network performance.
Configuration Procedures
The configuration procedures for the 701525-001 HPE 10GbE Dual-Port 561FLR-T Adapter will vary depending on the specific server and operating system being used. However, the general steps for configuring this adapter are as follows:
- Physically install the adapter into an available PCIe slot on the server.
- Install the appropriate driver for the operating system being used, either from the HPE website or the operating system’s driver repository.
- Configure the network settings for the adapter, including IP address, subnet mask, gateway, and DNS servers. This can usually be done through the operating system’s network configuration settings.
- If virtualization is being used, configure the adapter’s virtualization settings, such as VMware NetQueue or Microsoft VMQ. This may involve configuring the adapter through the virtualization platform’s management interface.
- If advanced features such as TCP/IP offload engine (TOE) or jumbo frames are being used, configure these settings through the adapter’s driver properties in the operating system.
- Verify that the adapter is functioning correctly by testing network connectivity and performance.
It is important to consult the adapter’s documentation and the operating system’s documentation for specific instructions and best practices when configuring the adapter. Additionally, HPE may provide configuration tools or utilities to help simplify the configuration process.
Thermal Considerations
Thermal considerations refer to the factors related to the heat generated by a hardware component, such as a network interface controller (NIC), and the impact of that heat on the component’s performance and longevity.
A NIC generates heat as it operates, and if that heat is not dissipated effectively, it can lead to thermal issues such as overheating, thermal throttling, and premature failure. These issues can impact the performance of the NIC, and in severe cases, can cause permanent damage.
To address these thermal considerations, NICs are designed to dissipate heat effectively. This can include the use of heat sinks or heat spreaders to increase the surface area available for heat dissipation, and the use of fans or other cooling mechanisms to increase airflow and dissipate heat.
It is important to ensure that a NIC is properly installed and that any cooling mechanisms are functioning properly. This may involve checking that the NIC is installed in a suitable location with adequate airflow, and ensuring that any fans or other cooling mechanisms are free of debris and functioning properly.
Additionally, it is important to consider the impact of other hardware components on the thermal performance of the NIC. For example, if a server or other hardware component is generating a significant amount of heat, this can impact the thermal performance of the NIC and may require additional cooling mechanisms to be put in place.
Main Specifications:
- Manufacturer: HPE
- MPN: 701525-001
- Spare Part Number: 700699-B21
- Type: Networking
- Adapter Type: Network Adapter 10 Gigabit
- Form Factor: Standard and low profile adapter compliant with the PCIe standard
- Interface (Bus) Type: PCI Express 2.1 (Gen 2) x8
Networking:
- Network Processor: Intel X540 Controller
- Data Rate: Two ports, each at 20 Gb/s bi-directional; 40 Gb/s aggregate bi-directional theoretical bandwidth.
- Connector: RJ-45 (Two)
- Ports: 10Gb Ethernet x 2
- Connectivity Technology: Wired
- Cabling Type: Ethernet 10GBase-T
- Data Link Protocol: 10 GigE
- Data Transfer Rate: 10 Gb/sec
- Remote Management Protocol: SNMP
- Status Indicators: Port status, link activity
- IEEE Compliance: 802.3, 802.3x, 802.3ad, 802.1Qaz, 802.1Qau, 802.1Qbb, 802.1ax
- Wiring: CAT6 UTP or better twisted-pair cabling
- Cable Distance: Maximum distances for CAT6 cable are 30 meters (98 feet). Maximum distances for CAT6A (or better) are 100 meters (328 feet).
- Features: Jumbo Frames Support, Teaming Support, PXE Support, Large Send Offload (LSO), Receive Side Scaling (RSS), TCP Segmentation Offload (TSO)
Processor/Memory:
- Processor: 1 x X540 – Intel
Expansion/Connectivity
- Interfaces: 2 x 10Gb Ethernet – RJ-45
- Miscellaneous
- RoHS Compliance: 6 of 6
- Safety Standards: UL Mark (USA and Canada), CE Mark, EN 60590
Agency Approvals
- USA: FCC Part 15 Class A
- Canada: ICES-003, Issue 4
- Japan: VCCI V3 (2010.04) Class A
- International: EN55022:2006 + A1:2007 Class A, EN55024:1998+A1:2011+A2; EN61000-3-2:2006, EN61000-3-3:2008
- Taiwan: BSMI, CNS13438 (2006) Class A
- Australia/New Zealand (AS/NZS): EN55022:2006+A12007 Class A
- Korea: KN22 Class A, KN24
System Requirements:
- OS Required: SunSoft Solaris 10, Microsoft Windows Server 2008 Foundation, SuSE Linux Enterprise Server 11, SuSE Linux Enterprise Server 10, Red Hat Enterprise Linux 5, Microsoft Windows Server 2008 Enterprise, Microsoft Windows Server 2008 Standard, Microsoft Windows Web Server 2008, Microsoft Windows Server 2008 Datacenter, Red Hat Enterprise Linux 6, Microsoft Windows Small Business Server 2011 Standard, Microsoft Windows Small Business Server 2011 Essentials, Microsoft Windows MultiPoint Server 2011, Citrix XenServer 6.0,
- Microsoft Windows Server 2012, SunSoft Solaris 11, Citrix XenServer 6.1, VMware vSphere 5.0, VMware vSphere 4.1
Product Dimensions & Weight
- Width: 9.50 inch
- Height: 2.25 inch
- Depth: 7.50 inch
- Weight: 1.00 lbs
Environmental Parameters
- Min Operating Temperature: 32 °F (0° C)
- Max Operating Temperature: 131 °F (55° C)
- Humidity Range Operating: 5 – 95% (non-condensing)
Compatibility Information
- HPE ProLiant DL (Gen9) Series: DL20 Gen9, DL60 Gen9, DL80 Gen9, DL120 Gen9, DL160 Gen9, DL180 Gen9, DL360 Gen9, DL380 Gen9, DL560 Gen9, DL580 Gen9
- HPE ProLiant DL (Gen8) Series: DL160 Gen8, DL160 Gen8 Base, DL160 Gen8 Entry, DL160 Gen8 Performance, DL360p Gen8, DL360p Gen8 Base, DL360p Gen8 CMS, DL360p Gen8 Entry, DL360p Gen8 High Performance, DL360p Gen8 Performance, DL380p Gen8, DL380p Gen8 Base, DL380p Gen8 Entry, DL380p Gen8 High Performance, DL380p Gen8 Performance, DL380p Gen8 Special, DL385p Gen8, DL385p Gen8 Dedicated Workload, DL385p Gen8 Entry, DL385p Gen8 Maximized Consolidation, DL385p Gen8 Storage, DL385p Gen8 Storage Centric, DL560 Gen8, DL560 Gen8 Base, DL560 Gen8 Entry, DL560 Gen8 Performance
- HPE ProLiant SL (Gen8) Series: SL230s Gen8 1U Left Half Width Tray, SL230s Gen8 1U Right Half Width Tray, SL230s Gen8 Base 1U Left Tray Server, SL230s Gen8 Base 1U Right Tray Server, SL250s Gen8 2U Left Half Width Tray, SL250s Gen8 2U PCIe Gen3 Left Tray, SL250s Gen8 2U PCIe Gen3 Right Tray, SL250s Gen8 2U Right Half Width Tray, SL250s Gen8 Base 2U Left Half Width Tray, SL250s Gen8 Base 2U Left Tray Server, SL250s Gen8 Base 2U Right Half Width Tray, SL250s Gen8 Base 2U Right Tray Server, SL270s Gen8 1U Left Half Width Tray, SL270s Gen8 1U Right Half Width Tray, SL270s Gen8 Base 4U Left Half Width Tray, SL270s Gen8 Base 4U Right Half Width Tray, SL270s Gen8 SE 4U Left Tray, SL270s Gen8 SE 4U Right Tray
- HPE Apollo (Gen9) Series: 2000 Gen9, 4200 Gen9, 4500 XL450 Gen9, 6000 XL230a Gen9, 6000 XL230b Gen9, 6000 XL250a Gen9