Description
Management and monitoring
The HPE C7000 Onboard DDR2 KVM Admin Module allows for the management and monitoring of the server blades within the C7000 chassis. This includes remote access to the server blades’ BIOS and other system settings, as well as providing virtual media support. This module provides a built-in keyboard, video, and mouse (KVM) administrative interface for managing the blades within the chassis. Additionally, the module allows for the monitoring of the health and status of the blades and the chassis, and can alert administrators to any issues that arise. It can be used with HPE’s Integrated Lights-Out (iLO) or Onboard Administrator (OA) management software to further enhance the monitoring and management capabilities of the C7000 chassis.
Troubleshooting
Troubleshooting the HPE C7000 Onboard DDR2 KVM Admin Module may involve several steps, depending on the specific issue encountered. Some common troubleshooting steps include:
- Verify that the module is properly seated in the C7000 chassis and that all necessary cables are securely connected.
- Check the status of the module in the Onboard Administrator (OA) or Integrated Lights-Out (iLO) management software to ensure that it is properly recognized and functioning.
- Check the system logs and event viewer for any error messages or alerts related to the module.
- Check the status of the blades and the chassis, and ensure that they are healthy and functioning correctly.
- Check for any firmware updates for the module and the blades, and apply them if necessary.
- Try resetting the module and the blades and see if the issue is resolved.
- If the problem persists, contact HPE support for further assistance.
It’s also important to check HPE documentation or knowledge base for specific troubleshooting steps or known issues related to the specific HPE C7000 Onboard DDR2 KVM Admin Module version.
Upgrading and replacement
Upgrading or replacing the HPE C7000 Onboard DDR2 KVM Admin Module may be necessary for several reasons, such as:
- To upgrade the firmware version for improved functionality or to fix bugs or security vulnerabilities.
- To upgrade the module’s hardware to support newer server blades or to add new features.
- To replace a faulty or defective module.
The upgrade or replacement process for the HPE C7000 Onboard DDR2 KVM Admin Module will depend on the specific version and model of the module. It’s important to check the HPE documentation or knowledge base for detailed instructions and compatibility information before proceeding.
In general, upgrading or replacing the module involves the following steps:
- Ensure that the C7000 chassis is powered off and all blades are removed.
- Carefully remove the existing module from the back of the chassis.
- Insert the new or upgraded module into the chassis and ensure that it is properly seated and connected.
- Power on the chassis and check that the new or upgraded module is recognized and functioning correctly.
- Upgrade the firmware and software if necessary.
It’s important to note that the replacement process of a module may cause some interruption in the service, and should be done with a proper downtime plan.
Detail Description
- Manufacturer: HPE
- MPN: 708046-001
- Type : Networking
- Management-Type : Remote Management
- SKU: 708046-001
- Type: Networking
- HPE BLC7000 onboard administrator with KVM option
- Green Compliant: Yes
- Green Compliance Certificate/Authority: WEEE; REACH
- c7000 Onboard Administrator DDR2 R2 with KVM ports – Collects thermal and power status, enables run-time management and configuration of the enclosure components, notifications
Dimension and Weight
- Height: 10inch
- Width: 18inch
- Depth: 12inch
- Weight: 3lbs